Welcome to Airpart - Min Order: €30.00
FREE EXPRESS SHIPPING TO SELECTED EU COUNTRIES – CLICK HERE FOR MORE INFORMATION.

Alcor Parts & Accessories

Complete Range of Alcor Instrument System Components

Tempest Alcor

Comprehensive Alcor System Components

Airpart Supply Europe distributes the complete range of Alcor parts and accessories for aviation instrument systems. Our inventory includes temperature monitoring components, lead extensions, adapters, selector switches, and installation hardware for professional aircraft maintenance operations.

This comprehensive parts range supports CHT temperature systems, EGT temperature systems, and TIT turbine monitoring across general aviation and turbine aircraft. Available components include Type J thermocouple lead extensions for cylinder head temperature applications, Type K thermocouple extensions for exhaust gas temperature monitoring, bayonet and weld boss mounting adapters, universal selector switches for multi-cylinder monitoring, and complete installation hardware for professional aircraft integration.

All Alcor parts and accessories maintain precise electrical specifications and resistance tolerances essential for accurate temperature measurement. From our Dublin warehouse, European maintenance organizations access genuine Tempest Alcor components with technical support for system installation and troubleshooting requirements.

Compatible with Alcor temperature instruments, test equipment systems, and aftermarket temperature monitoring solutions including JPI and Electronics International installations requiring Alcor probe compatibility.

Lead Extensions

Thermocouple Extension Leads for CHT and EGT Systems

CHT Type J

CHT Type J Lead Extension, 90"

Cylinder Head Temperature Extension Lead

Type J thermocouple extension lead for CHT applications. Black and Yellow wire identification. Resistance: 7.76 ± 0.20 Ω. 90 inch length configuration.

View Product

CHT Type J

CHT Type J Lead Extension, 144"

Extended Length CHT Lead

Type J thermocouple extension for cylinder head temperature monitoring. Black and Yellow coding. Resistance: 7.76 ± 0.20 Ω. 144 inch length for extended installations.

View Product

CHT Type J

CHT Type J Lead Extension, 216"

Long Configuration CHT Extension

Extended Type J thermocouple lead for CHT systems. Black and Yellow identification. Resistance: 7.76 ± 0.20 Ω. 216 inch length for complex installations.

View Product

CHT Type J

CHT Type J Lead Extension, 240"

Maximum Length CHT Extension

Maximum length Type J thermocouple extension for CHT applications. Black and Yellow wire coding. Resistance: 7.76 ± 0.20 Ω. 240 inch configuration.

View Product

EGT Type K

EGT Type K Extension Lead, 90"

Exhaust Gas Temperature Lead

Type K thermocouple extension for EGT and TIT applications. Red and Yellow wire identification. Resistance: 2.71 ± 0.06 Ω. 90 inch standard length.

View Product

EGT Type K

EGT Type K Lead Extension, 144"

Extended EGT Extension Lead

Type K thermocouple extension for exhaust gas temperature systems. Red and Yellow coding. Resistance: 4.34 ± 0.08 Ω. 144 inch extended configuration.

View Product

EGT Type K

EGT Type K Lead Extension, 216" C/A

Long Configuration EGT Lead

Extended Type K thermocouple lead for EGT/TIT monitoring. Red and Yellow identification. Resistance: 6.52 ± 0.11 Ω. 216 inch C/A specification.

View Product

EGT Type K

EGT Type K Lead Extension, 240"

Maximum Length EGT Extension

Maximum length Type K thermocouple extension for exhaust gas applications. Red and Yellow wire coding. Resistance: 7.25 ± 0.12 Ω. 240 inch configuration.

View Product

EGT Adapter

EGT Lead Stagger Adapter

Reverse Stagger Configuration

Lead stagger adapter for EGT and TIT sensor systems. Type K Red and Yellow configuration. Reverse sensor stagger specification for complex installations.

View Product

Adapters & Connectors

Mounting Adapters and System Interface Components

CHT Adapter

CHT Bayonet Adapter (3/8-24)

Bayonet Mount CHT Sensor

Bayonet mounting adapter for CHT sensor installations. 3/8-24 thread specification. Compatible with Alcor CHT probes and bayonet mounting systems.

View Product

Probe Adapter

JPI and EI to Alcor Probe Adapter

Aftermarket System Compatibility

Interface adapter for JPI and Electronics International systems to Alcor probes. Enables aftermarket instrument compatibility with existing Alcor sensor installations.

View Product

Copper Gasket

Gasket, Copper

Sensor Sealing Gasket

Copper gasket for Alcor sensor installations. Provides proper sealing for temperature probe mounting and prevents exhaust gas leakage at sensor locations.

View Product

Selector Switches & Installation Hardware

Cylinder Selectors, Mounting Hardware and Controls

2-Section Switch

Universal Cylinder Selector Switch, 2-Section

Standard Panel Selector Switch

Universal 2-section cylinder selector switch. 2-1/4 inch panel mount configuration. Enables manual selection between monitored cylinders or sensor positions.

View Product

4-Section Switch

Dual Universal Selector Switch, 4-Section

Multi-Position Cylinder Selector

Universal 4-section dual selector switch for multi-cylinder monitoring. 2-1/4 inch size. Allows simultaneous control of multiple temperature monitoring positions.

View Product

Mixture Control

Alcor Vernier Mixture Control

Precision Vernier Control

Vernier mixture control for aircraft carburetor systems. Precision adjustment mechanism for accurate mixture setting during flight operations and engine management.

View Product

Weld Boss

Weld Boss

Exhaust Stack Installation Fitting

Weld boss for EGT probe installations in exhaust stacks. 7/16-20 thread specification. Welded to exhaust system for permanent temperature probe mounting.

View Product

Boss Plug

Plug for Weld Boss 28113

Weld Boss Closure Plug

Closure plug for weld boss 28113. Seals unused probe ports in exhaust systems during maintenance, testing or when probe positions are not required.

View Product

Why Choose Alcor Parts & Accessories from Airpart Supply Europe

Comprehensive Component Range

Complete inventory covering thermocouple lead extensions for both CHT Type J and EGT Type K applications in multiple length configurations. Available lengths include 90 inch, 144 inch, 216 inch, and 240 inch extensions with precise resistance specifications for accurate temperature measurement. All lead extensions manufactured to exact electrical tolerances with proper wire color coding for positive identification during installation and maintenance procedures.

Mounting Adapters and Interface Hardware

Professional grade bayonet adapters, weld boss fittings, and probe interface adapters for permanent and removable sensor installations. Copper gaskets provide proper sealing at temperature probe locations preventing exhaust gas leakage and ensuring accurate temperature readings. JPI and Electronics International compatibility adapters enable aftermarket instrument systems to interface with existing Alcor probe installations, protecting sensor investment during avionics upgrades.

Universal Selector Switches

Panel-mounted cylinder selector switches in both 2-section and 4-section configurations for manual temperature monitoring control. Standard 2-1/4 inch panel cutout allows direct replacement of existing selector switches. Universal design compatible with Alcor temperature instruments and aftermarket monitoring systems enabling pilots to manually select monitored cylinders during engine operation and troubleshooting procedures.

EU Warehouse Dublin Stock

Immediate availability from our Dublin warehouse location serving European maintenance organizations with faster delivery times than transatlantic shipping. EASA-compliant documentation and technical specifications provided with all component shipments. Simplified VAT procedures for EU customers and competitive pricing on volume orders for maintenance facilities requiring multiple lead extensions and adapters for fleet instrument system maintenance programs.

Technical Application Support

Installation guidance and resistance verification specifications for proper thermocouple lead selection and system integration. Technical support for weld boss installation procedures, probe adapter applications, and selector switch wiring configurations. Compatibility information for interfacing Alcor sensors with aftermarket temperature monitoring systems including proper polarity connections and electrical specifications for Type J and Type K thermocouple circuits.

Related Alcor Products and Aviation Components

These Alcor parts and accessories complement our complete range of Tempest aviation products including Alcor temperature instruments, Alcor test equipment, and Alcor fuel treatment products.

Temperature Monitoring Systems: Complete integration with Alcor CHT, EGT, and TIT instruments for comprehensive engine temperature monitoring. Lead extensions and adapters enable proper sensor placement and instrument panel integration across single-engine, twin-engine, and turbine aircraft installations.

Engine Management Products: Compatible with Tempest oil filters, Tempest spark plugs, and complete aviation oils and lubricants for professional aircraft engine maintenance programs.

Testing and Calibration: Use with Alcor test equipment for system verification and troubleshooting. Proper lead extensions and adapters essential for accurate resistance measurements and thermocouple circuit testing during annual inspections and instrument calibration procedures.

Installation Hardware: Complete aircraft hardware and installation tools available for professional Alcor system installations including proper torque specifications and mounting requirements for temperature probe and weld boss installations.

Technical Information and Application Guidelines

Thermocouple Lead Specifications

Type J Thermocouple Leads: Black and Yellow wire identification with resistance specification of 7.76 ± 0.20 Ω. Used exclusively for CHT cylinder head temperature applications where temperature range and response characteristics match engine monitoring requirements. All Type J extensions maintain precise resistance tolerances ensuring accurate temperature measurement across the monitoring range.

Type K Thermocouple Leads: Red and Yellow wire identification with varying resistance based on length configuration. 90 inch leads specify 2.71 ± 0.06 Ω, 144 inch leads specify 4.34 ± 0.08 Ω, 216 inch configuration specifies 6.52 ± 0.11 Ω, and 240 inch maximum length specifies 7.25 ± 0.12 Ω. Type K extensions designed for EGT exhaust gas temperature and TIT turbine inlet temperature applications requiring higher temperature range capabilities.

Installation Hardware Applications

Weld Boss Installation: 7/16-20 thread specification weld boss requires proper welding procedures and exhaust system preparation. Boss installed in exhaust stack wall thickness with proper reinforcement and heat-affected zone considerations. Installation must maintain structural integrity of exhaust system while providing sealed mounting for temperature probes. Plug available for sealing unused boss locations during maintenance or when probe positions not required.

Bayonet Adapter Mounting: 3/8-24 thread bayonet adapter provides removable CHT probe installation in cylinder head spark plug ports. Proper torque specifications and copper gasket sealing essential for preventing combustion gas leakage and ensuring accurate temperature readings. Bayonet design enables probe removal for cylinder maintenance without disturbing permanent installations.

Selector Switch Configuration

Panel Integration: Universal selector switches require 2-1/4 inch panel cutout for standard instrument panel installation. Switches enable manual cylinder selection for single-gauge temperature monitoring systems where individual cylinder observation required during engine operation. Dual 4-section configuration allows simultaneous control of both CHT and EGT monitoring circuits in complex installations.

System Compatibility and Verification

Aftermarket Interface: JPI and Electronics International probe adapter enables connection of aftermarket monitoring instruments to existing Alcor temperature probes. Proper polarity verification essential during installation to maintain correct temperature indication. Resistance testing procedures confirm proper lead extension installation and electrical continuity through complete thermocouple circuit from probe to instrument panel gauge.

Contact Airpart Supply Europe

For Alcor parts and accessories availability, technical specifications, or volume pricing for maintenance organizations, contact our Dublin team.

Email: [email protected]

Phone: +353 1 699 4406